Please use this identifier to cite or link to this item: http://artemis.cslab.ece.ntua.gr:8080/jspui/handle/123456789/16500
Full metadata record
DC FieldValueLanguage
dc.contributor.authorΑνδρομάχη Καλταμπάνη
dc.date.accessioned2018-07-23T18:13:36Z-
dc.date.available2018-07-23T18:13:36Z-
dc.date.issued2012-11-27
dc.date.submitted2012-11-21
dc.identifier.urihttp://artemis-new.cslab.ece.ntua.gr:8080/jspui/handle/123456789/16500-
dc.description.abstractRecent advances in telecommunications technology and electronics have given a considerable boost to the development of implantable medical devices, which record and post-process crucial physiological signals of the human beings, and are capable of wirelessly communicating (telemetering) with exterior devices. The overall telemetry system consists of the implantable medical device and an external control device, which exchange data in real-time, thus contributing in the rapid diagnosis and treatment of several diseases. The band of 402-405 MHz, which is also known as the "Medical Implant Communications Service Band", has been allocated exclusively for the communication of these devices. The aim of this thesis is to design and study the performance of three exterior antennas (half-wavelength dipole, simple patch, miniaturized patch), which will be integrated on exterior control devices of medical telemetry systems for implantable devices operating at 402-405 MHz. Initially, the antennas are designed in free-space, and their resonance and radiation performance is evaluated in the same environment. Three-layer canonical models of the human head, arm and trunk are subsequently considered, and their effect on antenna performance is investigated, as a function of distance. A miniature implantable antenna, which has already been proposed in the literature, is further studied, and optimized for operation inside the skin-tissue of the three-layer head model (e.g. intra-cranial pressure monitoring). Finally, the performance of the telemetry link which is formed between the implantable antenna and the proposed exterior dipole antenna is evaluated. Patient safety issues and conformance with international safety guidelines are taken into account throughout this study. Numerical investigations are carried out using the Finite Element Method.
dc.languageGreek
dc.subjectmedical implant communications service (mics) band
dc.subjectbiotelemetry
dc.subjectexterior monitoring/control antennas
dc.subjectminiature patch antenna
dc.subjectcanonical models of biological tissues
dc.subjectspecific absorption rate (sar)
dc.subjectimplantable medical devices (imds)
dc.subjectwireless medical telemetry link
dc.titleΣχεδίαση Και Μελέτη Εξωτερικών Κεραιών Για Τηλεμετρία Με Εμφυτεύσιμες Ιατρικές Διατάξεις.
dc.typeDiploma Thesis
dc.description.pages111
dc.contributor.supervisorΝικήτα Κωνσταντίνα
dc.departmentΤομέας Συστημάτων Μετάδοσης Πληροφορίας & Τεχνολογίας Υλικών
dc.organizationΕΜΠ, Τμήμα Ηλεκτρολόγων Μηχανικών & Μηχανικών Υπολογιστών
Appears in Collections:Διπλωματικές Εργασίες - Theses

Files in This Item:
File SizeFormat 
DT2012-0292.pdf9.28 MBAdobe PDFView/Open